Independent mobile RV technicians across Dallas–Fort WorthFort WorthContact
Dallas RV Mechanic

RV Furnace Repair in Dallas–Fort Worth

Furnace blowing cold air, trying to light and giving up, or not coming on at all? An independent mobile RV technician can find the cause at your RV.

Independent mobile RV technicians come to you — home, storage lot or RV park.

Furnace exhaust vent on the side wall of an RV

If you smell propane: leave the RV, close the tank valve if it's safe to do so, and call 911 from a safe distance.

Signs your RV furnace needs a technician

How owners usually describe it, and what it often means.

  • The fan blows, but the air stays cold

    The furnace tried to light and failed. After three tries most furnaces stop and keep the fan off until you reset them at the thermostat. Common causes: no propane at the furnace, low 12-volt power, the sail switch, the igniter.

  • You hear it click, but there's no flame

    The igniter is sparking but the burner doesn't catch: no gas, a worn or dirty electrode, or a gas valve problem.

  • Nothing at all when you turn up the heat

    No fan, no click. Usually 12-volt power: a weak battery, a blown fuse, the thermostat or a loose wire.

  • It runs a few minutes, then shuts off

    Usually airflow: a blocked return grille, closed vents or crushed ducts make the furnace overheat, and a safety switch shuts it down.

  • The fan won't stop running

    A stuck relay, the thermostat or the control board. Not dangerous, but it drains the battery.

  • You smell propane

    Stop and leave the RV. See the warning at the top of this page.

What to check before you call

These checks come from the furnace makers' owner's manuals. None of them involve opening the furnace.

  • Propane

    Open the valve on the propane tank all the way. Check that the tank isn't empty — weigh it or read the gauge. If the stove burner lights, propane is reaching the RV.

  • 12-volt power

    The furnace fan and controls run on the 12-volt battery, even though the burner uses propane. A weak battery spins the fan too slowly, and the furnace won't light. Plug into shore power or charge the battery and try again. Check the furnace fuse in the 12-volt panel.

  • Thermostat

    Set it to Heat or Furnace and above room temperature. Replace the batteries if it has them.

  • Reset after three tries

    Suburban's manual says: if the burner doesn't light after three attempts, stop and call for service — don't keep switching the thermostat to force it. To reset the lockout once, turn the thermostat off and back on.

  • Return air and vents

    Move bedding, boxes or furniture away from the furnace's return grille and open the floor vents. The manual warns not to block the air going in or out.

  • Outside vent

    Look at the vent on the outside wall. Wasp and mud dauber nests and debris block it. Don't push anything metal inside.

Stop here. Don't remove the furnace, open the burner or adjust the gas valve. The manufacturer says service must be done by a qualified service agency, and in Texas propane work requires a license from the Railroad Commission (see below).

Hand in a leather work glove turning the valve of a propane tank on the front frame of a travel trailer

What the technician does

  1. Checks 12-volt power at the furnace while it tries to start.
  2. Tests the sail switch (it proves the fan is moving enough air) and the high-limit switch.
  3. Checks the igniter and the electrode gap, and the control board — newer boards flash a fault code.
  4. Checks the gas pressure at the appliance with a gauge, and the gas valve.
  5. Cleans the burner and the fan, and checks the vent and the ducts.
  6. Explains what failed and gives you a price before replacing parts.
Hands testing the screw terminals of a 12-volt terminal strip inside an RV with meter probes

Propane work in Texas

In Texas, work on an RV's propane system — gas lines, the regulator, gas valves and burners — is done by technicians licensed by the Railroad Commission of Texas. Before propane work starts, ask the technician for their license number. You can look it up on the Railroad Commission website.

What RV furnace repair costs

Typical 2026 ranges from an industry cost guide. They are U.S.-wide figures, not Dallas prices.

RepairTypical range
Igniter or electrode$150–450
Sail switch or limit switch$150–400
Control board$250–800
Blower motor$300–800
Gas valve$300–600
Technician labor$150–200 an hour

Source: Camping World, “RV Furnace Repair Cost Guide”, October 2026.

Typical range in 2026 — not a quote. The independent technician gives the price after diagnosis.

Most mobile technicians also charge a trip or diagnostic fee. Ask about it when you book.

What changes the price: the furnace model, whether the part is in stock, and how hard the furnace is to reach — in some RVs it sits behind a drawer or under a bed.

Prices checked November 2026.

Furnace return air grille near the floor on a cabinet base inside an RV

Brands and models

Most RV furnaces are Suburban (now Airxcel; SF, SFV, SH and SHD series) or Atwood Hydro Flame (now Dometic). The model and serial number are on a label behind the furnace's front cover or on the outside door. Have them ready when the technician calls.

Owner's manuals: Suburban SF, SFV, SH, SHD user's manual; more furnace manuals are in the Forest River component manuals.

RV furnace questions

Why would the furnace on an RV just stop working?

The most common causes are an empty or closed propane tank, a weak 12-volt battery, a blown fuse and a lockout after three failed tries. Check those first. If it still won't light, the sail switch, the igniter or the control board are next.

How much does it cost to fix a furnace in an RV?

In 2026, an igniter is about $150–450, a sail or limit switch $150–400, a control board $250–800, a blower motor $300–800 and a gas valve $300–600 (Camping World). Typical range in 2026 — not a quote. The independent technician gives the price after diagnosis.

What causes an RV furnace not to ignite?

No propane at the furnace, low 12-volt power that keeps the fan too slow for the sail switch, a dirty or worn electrode, or a failing control board or gas valve.

How do I reset my RV furnace?

Turn the thermostat off, wait a minute and turn it back on. That resets the lockout on Suburban furnaces and most others. If the furnace still doesn't light after three tries, stop and call a technician — the manufacturer says not to keep cycling it.

Why does my RV furnace keep blowing cold air?

The fan runs before and after the burner and keeps running if the burner fails to light. If the air never warms up, the furnace isn't lighting: check propane and 12-volt power, then reset at the thermostat once.

Request a technician

Tell us what's wrong and where your RV is. We send your request to independent mobile RV technicians who serve that part of DFW.

Request a technician