Independent mobile RV technicians across Dallas–Fort WorthFort WorthContact
Dallas RV Mechanic

RV Water Heater Repair in Dallas–Fort Worth

No hot water, the burner won't light, or the tank is leaking? An independent mobile RV technician can find the cause at your RV.

Independent mobile RV technicians come to you — home, storage lot or RV park.

Closed water heater access door with vent louvers on the side of an RV

If you smell propane: leave the RV, close the tank valve if it's safe to do so, and call 911 from a safe distance.

Signs your RV water heater needs a technician

How owners usually describe it, and what it often means.

  • No hot water on propane

    The burner tries to light three times and then locks out. Common causes: the propane is off or empty, air in a new gas line, a worn electrode or a tripped safety switch on the heater.

  • No hot water on electric

    The heating element, its switch or breaker, or the thermostat. An element that was switched on with an empty tank burns out — Suburban's manual warns about it.

  • Hot water for a minute, then cold

    The bypass valves are partly open, so cold water mixes into the hot line, or the tank is not heating fully.

  • It clicks but never lights

    Spark without flame: no gas reaching the burner, or a dirty electrode. If it doesn't click at all, check 12-volt power and the switch first.

  • Water drips from the relief valve

    A few drops while the water heats up is normal, according to Suburban. A steady stream or a leak from the tank itself is not.

  • Rotten egg smell from the hot water

    Usually a reaction between the water and the anode rod. Flushing the tank and replacing the anode usually fixes it.

What to check before you call

Suburban's owner's manual lists the first three checks before calling for service. None of them involve opening the burner.

  • The switch

    Make sure the water heater switch inside the RV is on. Many RVs have separate switches for gas and electric.

  • Propane

    Open the tank valve all the way and check that the tank isn't empty. After a new tank or a long break, the first start may take several tries while air leaves the gas line.

  • The reset button

    Suburban heaters have a reset button (the ECO switch) behind the outside door. If it tripped, the burner and the element won't work until it's pushed in.

  • Reset after a lockout

    If the burner fails three times, the heater locks out. Turn the switch off, wait five seconds and turn it back on.

  • Water in the tank

    Never turn on the electric element with an empty tank. Open a hot faucet: if only air comes out, the tank is empty or the bypass is set for winter.

  • Bypass valves

    In normal use the bypass valves behind the heater send water through the tank. If they are still set for winter storage, the tank stays empty or cold water mixes in.

Stop here. Don't open the burner, adjust the gas valve or try to light it by hand — the manual says it has no pilot and must not be lit by hand. If you see soot at the outside door, shut the heater off; the manual says to call a qualified service person right away.

Water heater bypass valves on the water lines behind an RV water heater tank

What the technician does

  1. Checks 12-volt power, the switch and the control board while the heater tries to light.
  2. Checks the electrode, the burner tube and the gas flow at the appliance.
  3. Tests the thermostat, the ECO safety switch and the electric element.
  4. Drains and flushes the tank and checks the anode rod.
  5. Checks the relief valve, the bypass valves and the fittings for leaks.
  6. Explains what failed and gives you a price before replacing parts or the heater.

Suburban recommends replacing the anode rod every year and sooner if it is mostly eaten away. A worn-out anode lets the steel tank rust from the inside.

Hands in knit work gloves holding a used anode rod just removed from an RV water heater

Propane work in Texas

In Texas, work on an RV's propane system — gas lines, the regulator, gas valves and burners — is done by technicians licensed by the Railroad Commission of Texas. Before propane work starts, ask the technician for their license number. You can look it up on the Railroad Commission website.

What RV water heater repair costs

Typical 2026 ranges from an industry cost guide. They are U.S.-wide figures, not Dallas prices.

RepairTypical range
Water heater repair$100–1,000+
Thermostat (part)$40–80
Electric heating element (part)$30–60
Anode rod (part)about $12
Replace the tank heater (labor)$200–400
Install an on-demand (tankless) heater (labor)$600–800

Source: Camping World, “Mobile RV Repair Cost Guide”, July 2026.

Typical range in 2026 — not a quote. The independent technician gives the price after diagnosis.

Technician labor in 2026 cost guides is about $140–200 an hour. Most mobile technicians also charge a trip or diagnostic fee — ask about it when you book.

What changes the price: gas, electric or both; tank size; whether the tank is leaking (then it's usually a new heater); and how easy the heater is to reach.

Prices checked November 2026.

Brands and models

Most tank water heaters in RVs are Suburban (SW series, now made by Airxcel) or Atwood (now Dometic). Suburban tanks are steel and use an anode rod; Atwood tanks are aluminum and don't take one. Many newer RVs have an on-demand (tankless) heater instead. The model and serial number are on a label behind the outside door.

Owner's manual: Suburban SW4D, SW6D, SW6DE, SW6DM, SW6DEM; more in the Forest River component manuals.

RV water heater questions

Can an RV hot water tank be repaired?

The parts can: the igniter, the thermostat, the safety switch, the element, the gas valve and the anode rod are all replaced on site. A tank that leaks from the tank itself is usually replaced as a whole heater.

Why is my RV propane water heater not lighting?

Most often the propane is off or empty, there is air in the gas line after a tank change, or the heater locked out after three tries. Turn the switch off for five seconds and back on. If it still won't light, call a technician.

Why is my RV water heater igniter not clicking?

No click usually means no 12-volt power at the control board, a switch that is off, or a tripped reset button behind the outside door. Check those first.

Why do I get hot water right away and then it turns cold?

Check the bypass valves behind the heater — if one is partly open, cold water mixes into the hot line. If they are set right, the tank may not be heating fully, and a technician should check the burner or the element.

Is it normal for the relief valve to drip?

Yes, a little. Suburban's manual says some dripping while the water heats is normal and does not mean the valve is bad. Never plug the relief valve.

Request a technician

Tell us what's wrong and where your RV is. We send your request to independent mobile RV technicians who serve that part of DFW.

Request a technician